Simulink Control Design™ - MathWorks
In the spec1 document, the Reference Filter block has one state. In the Simulink model window, double-click the Reference Filter ...
Click OK. This change increases the order of the filter, adding a state to the Simulink model. To update the operating point spe ...
The software updates the specifications. The Reference Filter block now has two states. Synchronize Simulink Model Changes with ...
To find the operating point that meets these specifications, on the Specification tab, click Trim. Synchronize Model Changes Usi ...
In the Simulink model window, double-click the Reference Filter block. Change the Numerator of the transfer function to 100 , an ...
To find the operating point that meets these specifications, click Start trimming Synchronize Model Changes at the Command Line ...
Create an operating point specification object based on the current model configuration. opspec = operspec(sys) Operating point ...
Change the transfer function of the Reference Filter block. Set the Numerator parameter to 100 and the Denominator parameter to ...
Outputs: None After you update the operating point specification object, the optimization algorithm successfully finds the oper ...
Find Steady-State Operating Points for Simscape Models You can find operating points for models with Simscape components using S ...
When using gradient descent with projection at the command line, you can specify whether the algorithm enforces the model initia ...
Functions findop | findopOptions | operspec Blocks PS-Simulink Converter More About “Find Steady-State Operating Points for Sim ...
Steady-State Simulation with Projection-Based Trim Optimizer This example shows how to find a steady-state operating point for a ...
Define Operating Point Specifications Before creating an operating point specification, configure the model to use the model ini ...
(2.92756e+00) scdbackhoeTRIM/Plant/Mounting Assembly/Mounting Base and Support Arms/Support Arm Left/Revolute Joint Arm (2.90835 ...
(1.34550e+00) scdbackhoeTRIM/Plant/Cylinder Base to Mounting Plate (1.34208e+00) scdbackhoeTRIM/Plant/Cylinder Base to Mounting ...
Steady-State Simulation with Projection-Based Trim Optimizer ...
The simulation results show that the five angles are trimmed to their expected values, however the trajectory deviates slightly ...
Generate MATLAB Code for Operating Point Configuration This topic shows how to generate MATLAB code for operating point configur ...
You can generate one of the following scripts: Live script — Click Live Script. The generated live script opens in the MATLAB L ...
«
4
5
6
7
8
9
10
11
12
13
»
Free download pdf