Microsoft Word - Cengel and Boles TOC _2-03-05_.doc
Chapter 10 | 595 water leaves the heater at the condensation temperature of the extracted steam and that the extracted steam lea ...
10–58 Reconsider Prob. 10–57. Using EES (or other) software, solve this problem by the diagram window data entry feature of EES. ...
Chapter 10 | 597 and the condenser pressure is 2 psia. Steam leaves the process heater as a saturated liquid. It is then mixed w ...
Combined Gas–Vapor Power Cycles 10–74C In combined gas–steam cycles, what is the energy source for the steam? 10–75C Why is the ...
Chapter 10 | 599 Review Problems 10–87 Show that the thermal efficiency of a combined gas–steam power plant hcccan be expressed ...
120 MW. Steam enters all three stages of the turbine at 500°C. The maximum pressure in the cycle is 15 MPa, and the minimum pres ...
Chapter 10 | 601 pressed liquid at 120°C. The mixture is then pumped to the boiler pressure. Assuming the turbine to be isentrop ...
602 | Thermodynamics 10–112 A simple ideal Rankine cycle operates between the pressure limits of 10 kPa and 3 MPa, with a turbin ...
Chapter 10 | 603 is cooled and condensed by the cooling water from a nearby river, which enters the adiabatic condenser at a rat ...
an engineering report describing your design. Your design report must include, but is not limited to, the following: (a) Discuss ...
Chapter 10 | 605 also by contacting some condenser manufacturers. In a report, describe the various types, the way they are desi ...
...
Chapter 11 REFRIGERATION CYCLES | 607 A major application area of thermodynamics is refrigera- tion, which is the transfer of he ...
11–1 ■ REFRIGERATORS AND HEAT PUMPS We all know from experience that heat flows in the direction of decreasing temperature, that ...
1 ton. One ton of refrigeration is equivalent to 211 kJ/min or 200 Btu/min. The cooling load of a typical 200-m^2 residence is i ...
The coefficients of performance of Carnot refrigerators and heat pumps are expressed in terms of temperatures as (11–4) and (11– ...
this isentropic compression process to well above the temperature of the sur- rounding medium. The refrigerant then enters the c ...
Another diagram frequently used in the analysis of vapor-compression refrigeration cycles is the P-hdiagram, as shown in Fig. 11 ...
Chapter 11 | 613 EXAMPLE 11–1 The Ideal Vapor-Compression Refrigeration Cycle A refrigerator uses refrigerant-134a as the workin ...
11–4 ■ ACTUAL VAPOR-COMPRESSION REFRIGERATION CYCLE An actual vapor-compression refrigeration cycle differs from the ideal one i ...
«
27
28
29
30
31
32
33
34
35
36
»
Free download pdf