Architectural and Engineering Design Standards

(avery) #1
SECTION 07550

MODIFIED BITUMEN MEMBRANE ROOFING (SBS)

Modified Bitumen Membrane Roofing (SBS)
UIHC #20X-0XX 07550-7


Polyolefin Burn Off
Film
Tensile Strength @ 73.4 " 36EF, 2
in/min

MD: 80 lbf/inch.
(14.1kN/m)
Elongation @ 73.4 " 36EF, 2
in/min

MD: 3.0%

(ASTM D-5147) CMD: 3.0%

Tear Strength @ 73.4 " 36EF, 2
in/min

MD: 100 lb

Low Temperature Flexibility -10ºF

2) Finished Finished Ply Sheet

Application Method Torch Applied
Nominal thickness 130 mil
Net Coverage 100 sq/ft (9.29 m²)
Compound SBS Modified Asphalt
Reinforcement Fibrous Glass Mat or
Scrim
Top Surface Mineral Surface
(white)

Bottom Surface Polypropylene or
Polyolefin Burn Off
Film
Tensile Strength @ 73.4 " 36EF, 2
in/min

MD: 80 lbf/inch.
(14.1kN/m)
(ASTM D-5147) CMD: 90 lb
(15.8 kN/cm)

Elongation @ 73.4 " 36EF, 2
in/min

MD: 3.0%

(ASTM D-5147) CMD: 3.0%

Tear Strength *(ASTM D5147)
2 in/min @ 73.4 ± 3.6ºF MD 100 lbf
Low Temperature Flex.
*(ASTM D 5147)

-10ºF