Comparison for 4/ 5/6 Stage Preheater (Estimation at 9500 TPD Capacity)
PH Stage Reduction
Remarks
Data Unit 4 stage 5 Stage 6 Stage
Power
generation
potential from
AQC with HAR
Gross
MW 7.26 7.44 7.66
Reduction in
exit losses
due to lesser
gas available
for AQC
(Combustion air
increases due to
higher Sp. Fuel
consumption)
Total power
generation
gross (PH +
AQC with HAR)
MW 17.30 14.55 13.20
Total power
generation net
( 94 % ) (PH
- AQC With
HAR)
MW 16.27 13.68 12.41
PH exit
operation gas
flow
m3/hr 1397811 1243444 1132394
30 mm pressure
drop in a
cyclone
SPC for pH fan
(w/o WHRS)
KW / of T
clinker
6.27 5.92 5.70
PH fan
operation flow
( with WHR )
m3/hr 971698 941176 896972
70 mm pressure
drop across
WHR boiler
Total Sp. Power
generation net
(PH + AQC
with HAR)
KW / of T
clinker
41.09 34.55 31.34
PH fan
operation
sp. Power
consumption
with WHRS
KW / of T
clinker 4.978 5.080 5.088